5. Solution

In this section several outputs will be specified before we have ANSYS solve.

Temperature

To specify the temperature as an output (Right Click) Solution > Insert > Thermal > Temperature, as shown below.


Click Here for Higher ResolutionVisit page in new window


Total Heat Flux

In order to have ANSYS solve for the Total Heat Flux, (Right Click) Solution > Insert > Thermal > Total Heat Flux, as shown below.


Click Here for Higher ResolutionVisit page in new window


Directional Heat Flux

In order to have ANSYS solve for the Directional Heat Flux, (Right Click) Solution > Insert > Thermal > Directional Heat Flux, as shown below.


Click Here for Higher ResolutionVisit page in new window


The default direction is set to x; however it can be changed within the "Details of of Directional Heat Flux" table.

Execute the Solver

In order to have ANSYS solve for the previously defined results (Click) Solve, .

Save

Save the project now. Do not close Mechanical.


Go to Step 6: Results

See and rate the complete Learning Module

Go to all ANSYS Learning Modules