You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 14 Next »

Unable to render {include} The included page could not be found.

6. Results

Temperature



Click Here for Higher ResolutionVisit page in new window


Total Heat Flux



Click Here for Higher ResolutionVisit page in new window

X Direction Heat Flux



Click Here for Higher ResolutionVisit page in new window

Temperature along Y=1m line

At this point we are interested in extracting the temperature values along the horizontal line, y=1m. First, (Right Click) Model > Insert > Construction Geometry as shown below.


Click Here for Higher ResolutionVisit page in new window


Next, (Right Click) Construction Geometry > Insert > Path as shown in the following image.


Click Here for Higher ResolutionVisit page in new window


Then, set Number of Sampling Points to 100, set Start X Coordinate to 0, set Start Y Coordinate to 1, set End X Coordinate to 1, and set End Y Coordinate to 1 as shown below.


Click Here for Higher ResolutionVisit page in new window


At this point another temperature output must be created. In order to create the temperature output (Right Click) Solution > Insert > Thermal > Temperature. In the "Details of Temperature 2" table set the Scoping Method to Path as shown below. Then, set Path to Path. Your "Details of Temperature 2" table should now look like the following image.


Click Here for Higher ResolutionVisit page in new window


Save

Save the project now. Do not close Mechanical.


Go to Step 7: Verification and Validation

See and rate the complete Learning Module

Go to all ANSYS Learning Modules

  • No labels