6. Results

Temperature



Click Here for Higher ResolutionVisit page in new window


Total Heat Flux



Click Here for Higher ResolutionVisit page in new window

X Direction Heat Flux



Click Here for Higher ResolutionVisit page in new window

Temperature along Y=1m line

At this point we are interested in extracting the temperature values along the horizontal line, y=1m. First, (Right Click) Model > Insert > Construction Geometry as shown below.

Next, (Right Click) Construction Geometry > Insert > Path as shown in the following image.

Then, set Number of Sampling Points to 100, set Start X Coordinate to 0, set Start Y Coordinate to 1, set End X Coordinate to 1, and set End Y Coordinate to 1 as shown below.

Save

Save the project now. Do not close Mechanical.


Go to Step 7: Verification and Validation

See and rate the complete Learning Module

Go to all ANSYS Learning Modules