AguaClara Philosophy of Design
Designs must...
- be constructable using local labor
- be consstructed using locally available materials
- use generic suppliers rather than specialized components
- operate without electricity
- consider cost and performance
- be robust
- optimize to obtain low-cost and high-performance
- be operator friendly
- Unit processes must be observable whenever possible (no sealed reactors)
- must be possible to operate plant without doing math
- Chemical dosages are set directly
- maintenance operations must be doable by 1 person
- direct reading indicator of plant flow rate
- chemical dosing control point must be close to flocculator
- have no small parts that can be easily lost
minimize use of valves to reduce costs
have removalable parts for inspection and maintenance
be sized so that all tanks are accessible by a human for inspection