Linear Flow Orifice Meter Design for 1000 L/min Flow Rate
The LFOM design with the smallest percent error has an initial H.flowloc = 1.5cm, and Pi.Lfomorifice = 20
This is a visual representation of the Riser pipe
- note: The bottom row of orifices calls for 51 orifices the drawing would not permit it so i put a large number of orifices in the bottom row.
This is the tabular form of the design
- The diameter is equal to 0.953 cm
Row
Height, cm
Number of orifices
0
0
51
1
2
34
2
3
14
3
4
13
4
5
13
5
6
11
6
7
10
7
8
9
8
9
10
9
10
7
10
11
9
11
12
8
12
13
7
13
14
7
14
15
7
15
16
7
16
17
6
17
18
6
18
19
7
19
20
6