Linear Flow Orifice Meter Design for 1000 L/min Flow Rate

The LFOM design with the smallest percent error has an initial H.flowloc = 1.5cm, and Pi.Lfomorifice = 20

This is a visual representation of the Riser pipe

  • note: The bottom row of orifices calls for 51 orifices the drawing would not permit it so i put a large number of orifices in the bottom row.

This is the tabular form of the design

  • The diameter is equal to 0.953 cm

    Row

    Height, cm

    Number of orifices

    0

    0

    51

    1

    2

    34

    2

    3

    14

    3

    4

    13

    4

    5

    13

    5

    6

    11

    6

    7

    10

    7

    8

    9

    8

    9

    10

    9

    10

    7

    10

    11

    9

    11

    12

    8

    12

    13

    7

    13

    14

    7

    14

    15

    7

    15

    16

    7

    16

    17

    6

    17

    18

    6

    18

    19

    7

    19

    20

    6