Linear Flow Orifice Meter Design for 500 L/min Flow Rate
The LFOM design with the smallest percent error has an initial H.flowloc = 1.5cm, and Pi.Lfomorifice = 20
This is a visual representation of the Riser pipe
This is the tabular form of the design
- The diameter is equal to 0.953 cm
Row
Height, cm
Number of orifices
0
0
26
1
2
16
2
3
7
3
4
7
4
5
7
5
6
5
6
7
5
7
8
4
8
9
5
9
10
5
10
11
3
11
12
4
12
13
4
13
14
4
14
15
3
15
16
3
16
17
4
17
18
3
18
19
3
19
20
2