Linear Flow Orifice Meter Design for 500 L/min Flow Rate

The LFOM design with the smallest percent error has an initial H.flowloc = 1.5cm, and Pi.Lfomorifice = 20

This is a visual representation of the Riser pipe

This is the tabular form of the design

  • The diameter is equal to 0.953 cm

    Row

    Height, cm

    Number of orifices

    0

    0

    26

    1

    2

    16

    2

    3

    7

    3

    4

    7

    4

    5

    7

    5

    6

    5

    6

    7

    5

    7

    8

    4

    8

    9

    5

    9

    10

    5

    10

    11

    3

    11

    12

    4

    12

    13

    4

    13

    14

    4

    14

    15

    3

    15

    16

    3

    16

    17

    4

    17

    18

    3

    18

    19

    3

    19

    20

    2