Sedimentation Prototype Final Report
Introduction
Methods
Initial Apparatus Setup
Unable to render embedded object: File (sed1.jpg) not found.
The initial apparatus set up was run by Process Controller which had functions set in place for when the system would turn on, off, or drain. It also included a pressure sensor that would control the flow rate of the system. It was found that the pressure sensor was unreliable and sensitive to changes in the environment. Additionally, the flocculator for this setup led to a high velocity gradient (G) of 129.1/s. This led to the formation of very small flocs.
New Apparatus Setup
Unable to render embedded object: File (sed2.jpg) not found.
Design Parameter
Equations
L/D
Vc
Straw Bundles
Unable to render embedded object: File (sed5.jpg) not found.
Type 1 Straws - 12mm
Unable to render embedded object: File (sed4.jpg) not found.
Type 2 Straws - 5mm
Unable to render embedded object: File (sed3.jpg) not found.
Type 3 Straws - 3mm