You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 5 Next »

General Program Information

Input Definitions

  • origin is the center point of the outlet of the first sedimentation tank
  • width.sed is the distance between the outlets of the sedimentation tanks or the width of the sedimentation tanks from the center line of the wall on either side of a tank
  • lvltank.dim is a 3,1 matrix with the x,y,z dimensions of the tank
  • Δ x is the distance in the x direction in a top view from the outlet of the first sedimentation tank (or the origin of the first pipe) to the outside wall of the leveling tank
  • Δ y is the distance in the y direction in a top view from the outlet of the first sedimentation tank (or the origin of the first pipe) to the outside wall of the leveling tank
  • Δ z is the distance in the z direction in a top view from the outlet of the first sedimentation tank (or the origin of the first pipe) to the bottom wall of the platform
  • lvltank.thick is the thickness of the walls of the leveling tank
  • thick.platform is the thickness of the platform
  • R1 is the inner radius of the pipes leading to the leveling tank
  • R.main is the inner radius of the effluent pipe
  • H.main is the height of the effluent pipe (or the water level in the leveling tank)
  • n is the number of sedimentation tanks
  • disp is the displacement of the center of the pipes coming up into the leveling tanks from the inside wall of the tank

Notes

  • All coordinates correspond to a top view.
  • The floor of the leveling tank is at the same elevation as the top of the platform