Numerical Solution

Set up an animation

  • Highlight Calculation activities. Click in "Create/Edit" under "Solution Animations".
    • If the button is grayed out, close Fluent, open Solution of the MFR, close it and then re-open Solution for the Sliding Mesh.
    • Increase "Animation Sequences" to 1.
    • Rename it to Sliding_Mesh
    • Change "When" to Time Step and click Define.
      • Display type will be "Contours"
        • Change contours to Velocity, deselect all Surfaces.
        • Check "Filled", uncheck "Global Range", "Auto Range" and Clip to Range".
        • Set the "max" to 16.
        • Click Display
        • Zoom in and adjust the display so that the turbine is slightly to the left, and you can see the wake. This scene will be the animation close-up that will be created.
      • Close the Windows (click Close, Ok and Ok).

 

Run Calculation

  • Highlight Monitors and delete the two Moment Monitors created before.
    • Create a new Moment Monitor. Select Plot and Print, change the window to 2 and select the three bottom wall zones. Verify that the Center and Axis are correct and Click Ok.
  • Click on Run Calculation.
    • Time step size: 0.005s
    • 300 Time steps
    • Data File Quantities and select Vorticity Magnitude
    • Click "Calculate"!


Go to Step 6: Numerical Results

Go to all (ANSYS or FLUENT) Learning Modules