 Silicone vs. No Silicone (No wind)

The tests were done with the medium cooker built in Fall '08. Each test had 5lb of water in
1 pot, centered. Tests were run to assess the significance of adding silicone caulking on the
outside and inside glass panes.
The time it took to run a standard test without silicone is 51.9 minutes, which falls between
the 95% confidence interval of the tests with silicone, between 50.16 and 52.89 minutes
with a mean of 51.53 minutes. Therefore, there is no statistically significant difference at a
95% confidence level. However, we ran only one test in the without silicone no wind
condition and this may contribute to the statistical insignificance.

 

Time, in minutes

Average of the standard tests with silicone

51.525

Standard deviation of standard tests with silicone

1.391342

Significance level

0.05

Confidence

1.36349

Confidence interval

50.16-52.89