Linear Flow Orifice Meter Design for 300 L/min Flow Rate and 10 rows
The LFOM design with the eaiest construction has an initial H.flowloc = 1.5cm, and Pi.Lfomorifice = 10
This is a visual representation of the Riser pipe
This is the tabular form of the design
- The diameter is equal to 1.746 cm
Row
Height, cm
Number of orifices
0
0
5
1
2
3
2
4
2
3
6
3
4
8
1
5
10
2
6
12
1
7
14
1
8
16
2
9
18
1
10
20
1