You are viewing an old version of this page. View the current version.

Compare with Current View Page History

Version 1 Next »

Unable to render {include} The included page could not be found.
Unable to render {include} The included page could not be found.

Stepped Shaft: Pre-Analysis and Start-Up

Pre-Analysis

It is recommended that you make some back-of-the-envelope estimates of expected results before launching into your computer solution. Here
!roarke_formula1.png|width=200!\
for which the following formula for the axial stress concentration factor, K, holds (Roark's Formulas for Stress and Strain, Warren C. Young and Richard G. Budynas, 2002):
!roarke_formula2.png|width=380!\
We'll compare the above axial stress concentration factor to the value obtained from ANSYS.

Start-Up

Launch ANSYS Workbench and start a "Static Structural" analysis in the project page as shown in the video below.


Continue to Step 2 - Geometry

Go to all ANSYS Learning Modules

  • No labels