You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 12 Next »

Unable to render {include} The included page could not be found.

Exercise

Problem Statement

Consider a pair of concentric cylinders with a height of 24 mm. The smaller cylinder has a radius of 12 mm. The inner and outer radius of the larger, hollow cylinder is 24 mm and 25 mm, respectively. The same boundary condition and the initial condition from the shell and specimen tutorial will be used: Convection on the outer surface of the larger, hollow cylinder, and two radiation boundary conditions for each emitting surface. The larger, hollow cylinder will be set to 22 degress Celsius and the smaller cylinder will be set to -273.15 degrees Celsius.


click here for full view

Analytic Solution

Assume only the inner surface of the larger, hollow cylinder and the cylindrical surface of the smaller cylinder are emitting radiation. Also assume the surfaces are gray and diffuse. The net radiation of a emitting surface of this concentric cylinder, two-surface enclosure is give below:

In this convention, the subscript "1" denotes the smaller cylinder and the subscript "2" denotes the larger, hollow cylinder. Since this is a two-surface enclosure problem, we can expect the view factor for each surface to be 1. All the radiation emitted by one surface is intercepted by the other surface. The notation of the above equation is the net radiation of the smaller cylinder.

The analytic solution shows the net radiation of the smaller cylinder is -0.428 watts.

ANSYS result

Solve this problem with the same procedure for the shell and specimen tutorial. First solve the steady state model and transfer the data to transient analysis to complete the simulation. Make sure you use the same step end time and the same boundary and initial conditions.

From the tabular data, the net radiation of the smaller cylinder is -0.423 watts at the step end time. ANSYS result shows a 1.4% deviation from the analytic solution. Hence we can verify that the view factor and radiation heat transfer are computed correctly in this set up. This also verifies the validity of the shell and specimen model.

  • No labels