You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 7 Next »

Unable to render {include} The included page could not be found.

Under Construction

This page is under construction. Please return later for updates

Solution

Solution Methods

In the Outline window, select Solution Methods to open the Solution Methods window. Under Spatial Discretization, the option under Momentum from First Order Upwind to Second Order Upwind. Under Energy, also change the option to Second Order Upwind.



Monitors

In the Outline window, click Monitors to open the Monitors window. In the Monitors window, select Residuals - Print,Plot and press Edit.... This will open the Residual Monitors window. We want to change the convergence criteria for our solution. Under Equation and to the right of Continuity, change the Absolute Criteria to 1e-6. Repeat for x-velocity, y-velocity, and energy, then press OK.

Solution Initialization

In the Outline window, select Solution Initialization. We need to make an "Initial Guess" to the solution so FLUENT can iterate to find the final solution. In the Solution Initialization window, under Compute from, select Inlet from the drop down box. Check to see that the values that generate match our inputted values, then press Initialize

Run Calculation

In the Outline window, select Run Calculation. Change the Number of Iterations to 200. Double click Calculate to run the calculation. After the calculation is complete, save the project, and you may close the solver.

Go to Step 6 - Results

  • No labels