You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 27 Next »

Under Construction!!

4. Setup (Physics)

Launch Fluent

(Double Click) Setup in the Workbench Project Page. Select Double Precision. Then click OK

Check Mesh

(Click) Mesh > Info > Size
You should now have an output in the command pane stating that there are 18,432 cells.

(Click) Mesh > Check
You should see no errors in the command pane.

Specify Material Properties

Problem Setup > Materials > Fluid > Create/Edit....
Then set the Density to 1 kg/m^3 and set Viscosity to 0.05 kg/m*s. Click Change/Create then click Close.

Boundary Conditions

FarField1

Problem Setup > Boundary Conditions > farfield1.
Set Type to velocity-inlet. Click Edit.... Set Velocity Specification Method to Components, set X-Velocity to 1 m/s, and set Y-Velocity to 0 m/s.

FarField2

Problem Setup > Boundary Conditions > farfield2..
Set Type to pressure-outlet.

Cylinder Wall

Problem Setup > Boundary Conditions > cylinderwall.
Set Type to wall.

Reference Values

Problem Setup > Reference Values.
Set the Density to 1 kg/m^3. The other default values will work for the purposes of this simulation.

Go to Step 5: Solution

See and rate the complete Learning Module

Go to all FLUENT Learning Modules