Author: John Singleton and Rajesh Bhaskaran
Problem Specification
1. Pre-Analysis & Start-Up
2. Geometry
3. Mesh
4. Setup (Physics)
5. Solution
6. Results
7. Verification and Validation
Exercises
Under Construction!!
Setup (Physics)
Launch Fluent
(Double Click) Setup. Select Double Precision. Then click OK
Specify Material Properties
Problem Setup > Materials > Fluid > Create/Edit.... Then set the Density to 1 kg/m^3 and set Viscosity to 0.05 kg/m*s. Click Change/Create then click Close.
Boundary Conditions
FarField1
Problem Setup > Boundary Conditions > farfield1. Set Type to velocity-inlet. Click Edit.... Set Velocity Specification Method to Components, set X-Velocity to 1 m/s, and set Y-Velocity to 0 m/s.
FarField2
Problem Setup > Boundary Conditions > farfield2.. Set Type to pressure-outlet.
Cylinder Wall
Problem Setup > Boundary Conditions > cylinderwall. Set Type to wall.
Reference Values
Problem Setup > Reference Values
Go to Step 5: Solution
See and rate the complete Learning Module