Series of Orifices Design

Summary

Another proposed design was to use a series of orifices within a tube that supplies the alum stock to the untreated water. Given the head loss that these orifices would provide, we needed to determine if the resulting alum flow would be slow enough to dose the water appropriately. To do this, we allowed a 20-percent error (since the dose was not intended for flocculation) and looked at the range of flow given this allowable error and the constant decrease in alum solution level. Unfortunately, we found that the resulting flow of alum from this design was too large for our purposes.

Calculations

Download the Series of Orifices Design MathCAD file here.

The head loss in the tube was determined using the equations for major and minor losses. The equations used in these calculations were found in online AguaClara notes and in Frank M. White's Fluid Mechanics (6th Edition).