You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 6 Next »

Step 5: Solve!

Set Solution Controls

Main Menu > Solve > Controls > Solution...

Select PISO from the Pressure-Velocity Coupling drop-down list.

PISO allows the use of higher time step size without affecting the stability of the solution. Hence it is recommended pressure-velocity coupling for solving transient applications.

Uncheck Skewnes-Neighbor Coupling.

Select Second Order Upwind from the Momentum drop-down list in the Discretization group box. Click OK to close the Solution Controls panel.

Set Initial Guess

Initialize the flow field to the values at the inlet:

Main Menu > Solve > Initialize > Initialize...

In the Solution Initialization menu that comes up, choose inlet under Compute From. The X Velocity for all cells will be set to 1 m/s, the Y Velocity to 0 m/s and the Gauge Pressure to 0 Pa. These values have been taken from the inlet boundary condition.
 
 Click Init. This completes the initialization. Close the window.

 
 
Go to Step 3: Specify Boundary Types in GAMBIT

See and rate the complete Learning Module

Go to all FLUENT Learning Modules

  • No labels