Flow Rate (L/min) | Max Error % | Pi_LfomOrifice(the number of rows) | LFOM Design |
---|---|---|---|
100 | 0.398 | 20 | |
200 | 0.14 | 20 | |
300 | 0.195 | 20 | |
400 | 0.109 | 20 | |
500 | 0.097 | 20 | |
700 | 0.046 | 20 | |
1000 | 0.049 | 20 |
The Mathcad Entrance Tank Code was run for seven flow rates, three Pi_LfomOrifice values, and two initial values for the H.flowloc array. The excel spreadsheet with the original data is available here. The Entrance Tank Code is available through the SourceForge repository, a storage system. To access the code follow these folders: design repository -> Automated Design -> Design -> EntranceTank.