Flow Rate (L/min)

Max Error %

Pi_LfomOrifice(the number of rows)

LFOM Design

100

0.398

20

Design

200

0.14

20

Design

300

0.195

20

 Design

400

0.109

20

 Design

500

0.097

20

 Design

700

0.046

20

 Design

1000

0.049

20

 Design

The Mathcad Entrance Tank Code was run for seven flow rates, three Pi_LfomOrifice values, and two initial values for the H.flowloc array. The excel spreadsheet with the original data is available here. The Entrance Tank Code is available through the SourceForge repository, a storage system. To access the code follow these folders: design repository -> Automated Design -> Design -> EntranceTank.