Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

Sedimentation

...

Prototype

...

Final

...

Report

Introduction

Methods

Initial Apparatus Setup

Image Added
Initial Apparatus Setup
The initial apparatus set up was run by Process Controller which had functions set in place for when the system would turn on, off, or drain. It also included a pressure sensor that would control the flow rate of the system. It was found that the pressure sensor was unreliable and sensitive to changes in the environment. Additionally, the flocculator for this setup led to a high velocity gradient (G) of 129.1/s.

...

This

...

led

...

to

...

the

...

formation

...

of

...

very

...

small

...

flocs.

...


New Apparatus Setup

Image Added

Design Parameter

Equations

L/D

Vc

Straw Bundles

Image Added
Type 1 Straws - 12mm

Image Added
Type 2 Straws - 5mm

Image Added
Type 3 Straws - 3mm

Results & Discussion

Conclusions