Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

From the Ansys Mechanical APDL Verification Manual problem VM119 the calculated centerline temperature was 420.0 F (215.6 C). The percent error between these two calculations is 0.102%. In conclusion, the solvers calculation for the centerline temperature is accurate.  

 

Simulation Value

Verification Value

% Difference

215.38

215.6

0.102%

 


Go to all ( ANSYS or FLUENT) AIM Learning Modules