Include Page | ||||
---|---|---|---|---|
|
Include Page | ||||
---|---|---|---|---|
|
Verification & Validation
From the Ansys Mechanical APDL Verification Manual problem VM119 the calculated centerline temperature was 420.0 F (215.6 C). The percent error between these two calculations is 0.102%. In conclusion, the solvers calculation for the centerline temperature is accurate.
...
Simulation Value | Verification Value | % Difference |
215.38 | 215.6 | 0.102% |
Go to all ( ANSYS or FLUENT) AIM Learning Modules