First, (Right Click) Model > Insert > Construction Geometry as shown below.


newwindow
Click Here for Higher Resolution
Click Here for Higher Resolution
https://confluence.cornell.edu/download/attachments/146918520/InsConstructGeomFull.PNG


Next, (Right Click) Construction Geometry > Insert > Path as shown in the following image.


newwindow
Click Here for Higher Resolution
Click Here for Higher Resolution
https://confluence.cornell.edu/download/attachments/146918520/InsertPath_Full.PNG
Name

Re-name this path as Right Edge y=1, then set Number of Sampling Points to 100. Set Start X Coordinate to 0, set Start Y Coordinate to 1, set End X Coordinate to 1, and set End Y Coordinate to 1 as shown below. This sets the start and end points for the path.

...

At this point, another temperature output must be created under Solution in the tree. In order to create this temperature output, (Right Click) Solution > Insert > Thermal > Temperature. In the "Details of Temperature 2" table set the Scoping Method to Path as shown below. Then, set Path to Right Edge ( y=1 (if you did not rename the path to y=1, you'll see the default name for the path that was just created is path path instead.) Your "Details of Temperature 2" table should now look like the following image.
Image Removed
Image Added


(Click) Solve, , and ANSYS will find the temperature on the line y=1 m as a function of the distance along the path, which in this case is the x position. ANSYS will obtain the temperature for 100 points on the line y=1m. The data points are displayed in a table and can be exported to a text file or EXCEL file by right-clicking on the table.

...