Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

To find the temperature at the wall, click on insert >> location >> point, and name it Tw exit. In the Details of Tw exit window, set Method to XYZ and enter (8.64, 0.06, 0) in Point. Click Apply to create a point at the upper right corner of the pipe. Click on Expression right below and right click in the window to create a new expression named Tw. Under Details of Tw panel, enter probe(Temperature)@Tw exit in the Definition tab. Tw now gives the temperature at the location (8.64, 0.06, 0), which is on the exit pipe wall.

...