Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

Note

Under Construction!!

4. Setup (Physics)

Duplicate Steady Flow Project

First, complete the Steady Flow Past a Cylinder Tutorial. In the Workbench Project Page of your steady flow project, (Right Click) Solution > Duplicate

...

Launch FLUENT.

(Double Click) Setup in "Unsteady Flow", the duplicate project. Select Double Precision, and if using a computer with multiple cores, select parallel, and set the number of cores to be used.

Image Added

Then click OK

Transient

In this step here we will, tell FLUENT to solve for the unsteady flow. As you can see, by default FLUENT will solve for the steady flow.

Problem Setup > General. Set Time to Transient.

Image Added

Specify Material Properties

To achieve a Reynolds number of 120, as required in the problem statement, we will change the material viscosity, to 8.333*10^-3 kg/m*s.

Problem Setup > Materials > Fluid > Create/Edit.... Set the viscosity to 8.333*10^-3 kg/m*s. Click Change/Create then click close.

Image Added

Then click Close.

Save Project



Go to Step 5: Solution

See and rate the complete Learning Module

Go to all FLUENT Learning Modules