Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

A new Wall window will open. Click on Thermal tab and enter 34735210.9 85 next to Heat Flux (w/m2) and click OK.

Image RemovedImage Added

newwindow
Higher Resolution Image
Higher Resolution Image
https://confluence.cornell.edu/download/attachments/111221574/heated%20wall.png

...

Click Edit... to set up the correct inlet parameters. The Velocity Inlet window pops up. Enter 2530.05 06 next to Velocity Magnitude (m/s). For Turbulent Kinetic Energy (m2/s2), enter value 0.09. For Turbulent Dissipation Rate (m2/s3), enter value 16. Note that k and epsilon are not measured and are rough guess values. The results should not be sensitive to these inputs since most of the turbulence is generated in the boundary layers (ideally, you should check the sensitivity of your calculation to this setting). 

Image RemovedImage Added

newwindow
Higher Resolution Image
Higher Resolution Image
https://confluence.cornell.edu/download/attachments/111221574/velocity%20inlet_sm.png

...