The thickness of the spar is 0.02 meters. Locate the appropriate surface bodies that represent the spar and change the thickness to 0.02 meters.

Connections

The contact between the wind blade and the spar needs to be modeled. Right click on Connections and insert a Connection Group.

Image Added

In the connection group named Contacts 2, change the Face/Face detection to No and Face/Edge detection to Yes.

Image Added

Right click on Contacts 2 and click on Create Automatic Connections.

Image Added

Material Properties

For each surface body, check that Structural Steel is assigned as the material.

...