In the Viscous Model window, choose k-epsilon (2 eqn) for Model. Choose Realizable for k-epsilon Model. Choose Enhanced Wall Treatment for Near-Wall Treatment. Click OK as shown in the figure below.
Next, click on Solution Methods tab on the left hand side pane. Choose Second Order Upwind for Turbulent Kinetic Energy and Turbulent Dissipation Rate.
Higher Resolution Image
Click on Monitors > Residual and click Edit.... Set 1e-06 for k and epsilon and click OK.
...
Click on Solution Initialization and click Compute from and choose inlet.Click initialize as shown below.
Click on Run Calculation and set Number of Iterations to 1000.Click Calculate as shown below.
Higher Resolution Image
The solution converges in about iterations.
Go to Problem Specification