Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

The right side of the rectangle has a convective boundary condition with a Biot Number of 5 and ambient temperature of 0. To implement this boundary condition, (Right Click) Steady-State Thermal > Insert > Convection , as shown below.


newwindow
Click Here for Higher Resolution
Click Here for Higher Resolution
https://confluence.cornell.edu/download/attachments/146918515/InsConv_Full.png


Next, click on the right side of the rectangle and (Click) Apply in the "Details of Convection" table. Then, set the Film Coefficient (i.e. convection coefficient) to 5 W/(m^2 C) and set the Ambient temperature to 0 degrees Celsius, as shown below.


newwindow
Click Here for Higher Resolution
Click Here for Higher Resolution
https://confluence.cornell.edu/download/attachments/146918515/DetConv_Full.png


This , concludes the setup process.

...