The bottom side of the rectangular domain has a constant temperature of theta=1. To implement this boundary condition, (Right Click) Steady-State Thermal > Insert > Temperature , as shown below.
newwindow |
---|
| Click Here for Higher Resolution |
---|
| Click Here for Higher Resolution |
---|
|
https://confluence.cornell.edu/download/attachments/146918515/InsTemp_Full.png |
Next, click on the bottom side of the rectangle and
(Click) Apply in the "Details of Temperature" table. Then, set
Magnitude to 1 degree Celsius as shown below.
newwindow |
---|
| Click Here for Higher Resolution |
---|
| Click Here for Higher Resolution |
---|
|
https://confluence.cornell.edu/download/attachments/146918515/SetTemp_Full.png |
Convective Boundary
The right side of the rectangle has a convective boundary condition with a Biot Number of 5 and and ambient temperature of 0. To implement this boundary condition, (Right Click) Steady-State Thermal > Insert > Convection , as shown below.
Image Added
newwindow |
---|
| Click Here for Higher Resolution |
---|
| Click Here for Higher Resolution |
---|
|
https://confluence.cornell.edu/download/attachments/146918515/InsConv_Full.png |
Next, click on the right side of the rectangle and (Click) Apply in the "Details of Convection" table. Then, set the Film Coefficient to 5 and set the Ambient temperature to 0 degrees Celsius, as shown below. Image Addednewwindow |
---|
| Click Here for Higher Resolution |
---|
| Click Here for Higher Resolution |
---|
|
https://confluence.cornell.edu/download/attachments/146918515/DetConv_Full.png |
This, concludes the setup process.