Sensor Development Team

 

Excerpt

The primary goals goal of this team are to develop a gas measurement sensor that can be used in AguaClara plants, as well as design and build a fluidized bed solids concentrator sensor.is to build sensors to assist the wastewater subteams. The first semester of the Sensor Development team focused on building a biogas sensor and a fluidized bed solids concentration sensor. The next semester, the team modified the fluidized bed solids concentration sensor to fit the needs of the High Rate Sedimentation (HRS) team. The team also designed and built a submersible concentration sensor to measure the height of the sludge blanket.  

Fall 2017

 

Spring 2017

The Sensor Development Team modified the solids concentrator sensor for the HRS team recirculators. The primary goal this semester is to determine an accurate calibration curve of clay concentrations in HRS recirculators using the existing photosensor LED light. The calibration curve was created by testing the photosensor with various concentrations of clay. Then, the calibration curve to convert voltage readings to concentration. Next, a submersible concentration sensor was designed, which will be used to measure the height of the sludge blanket in the sedimentation tank. The design of the submersible sensor consisted of a photometer attached to the end of a 2 m marked pipe. As the sensor is lowered into the sedimentation tank, the photometer measures the voltage. When the photometer reads the dark voltage, due to the high concentration of the sludge blanket, the height of the sludge blanket can be read from the markings on the pipe. Fabrication of the submersible sensor was completed this semester, and the next steps for the Sensor Development subteam are to test the sensor and optimize it for portability.  

Fall 2016

The Sensor Development Team is a new team for the Fall 2016 semester. The team was created in response to the needs of the ASB UASB and AFB teams. The primary goals of this team are were to develop a gas measurement sensor that can be used in AguaClara plantswastewater subteams, as well as design and build a fluidized bed solids concentrator sensor that can be used by other AguaClara subteams. This semester, we will finalize finalized a method of gas measurement, program programmed settings in PoCoDa ProCoDa to automate the systems, and build built the next generation of the measurement system. We will then evaluate and troubleshoot the new system, with the possibility of designing a new system if improvement is needed. For the fluidized bed solids concentrator sensor, we will first run tests and take measurements of the photosensor output. Next, we will develop a method to correlate photosensor output to the existing intensity of fluidized solidsbuilt and calibrated a sensor that detects LED light shining through a clear PVC pipe containing granules to output granule concentrations in ProCoDa for the AFB team. This sensor can be modified for other subteams, as needed.

Current & Future Research
Section
Column
Current Team Members Fall 2017

Grace Zhang (tz76@cornell.edu)

Lois Lee (ll556@cornell.edu)

Srilekha Vangavolu (sv397@cornell.edu)

Former Team Members Spring 2017

Cheer Tsang (ct542@cornell.edu)

Luna Oiwa (lo72@cornell.edu)

Jingfei Wang (jw785@cornell.edu)

Former Team Members Fall 2016

Sidney Lok (sgl38sgl38@cornell.edu)

Grace Mitchell (gmm93@cornell.edu)

Andrea Pozo (ap989@cornell.edu)

Cheer Tsang (ct542@cornell.edu)

Column
Team Documents
Column
Past Research

None.

 

...