Results > Graphics and Animations > Contours > Set Up...
Set Contours of to Velocity.. and set the box below to Vorticity Magnitude. Then click Display. The plot below was created by by setting levels to 60, deselecting Auto Range, setting Min (1/s) to 0.25 and setting Max (1/s) to 9.


newwindow
Higher Resolution Image
Higher Resolution Image
https://confluence.cornell.edu/download/attachments/144972154/Vort_Full.png

...

Reports > Result Reports > Forces > Setup
Then, click Print. The command pane will now display the following results: the pressure force, the viscous force, the total force, the pressure force coefficient, the viscous force coefficient and the drag force coefficient. As one can see from the following image link, FLUENT yields 2.04 for the value of the drag coefficient.

newwindow
Drag Coefficient
Drag Coefficient
https://confluence.cornell.edu/download/attachments/144972154/DragCoeff_Full.png