  • Cut pex tubing into .051 m pieces to use as spacers
  • Finished second set of adjustable baffles to allow for hot swapping
  • Cut and capped rapid mix tube to allow for higher plant flows since water level in the tube was already very high for a low flow rate and would overflow if increased
  • Fixed where dosing of alum (or PAC) was taking place to guarantee appropriate mixing of coagulant before flocculation
    • Before the coagulant took a really long time to get into the flocculator due to water backing up.
  • Set up plant for dosing with polyaluminum chloride (PAC)
  • Determined method for normalizing turbidity profile data
  • Set up flow meter to read in L/min

...