Q = 100 L/min
K.baffle = 4
Π.cell = 1
w = 12 in.305 m
b = various spacings (in)
b (inm) | ε (mW/kg) |
2" .0051 | 49.099 |
3" .076 | 9.699 |
4" .102 | 3.069 |
5" .127 | 1.257 |
6" .152 | 0.606 |
7" .178 | 0.327 |
8" .203 | 0.192 |
Outcomes
- Have range of values of spacings to be tested with adjustable baffle system to find an optimal energy dissipation rate. With both sets of baffles done and a range of dissipation rates to test we can turn on the plant and begin taking turbidity profiles.
...