Analysis of the effect of alum dose and flocculator length on flocculation

Introduction

The goal of this experiment is to study the effects of different alum doses and flocculator lengths in order to find the most effective way to improve the performance of the actual AguaClara flocculator. A well performing flocculator produces flocs of certain sizes that can settle in the sedimentation tank or aid in the formation of a floc blanket resulting in a low effluent turbidity indicating the production of clean water.

The use of alum is necessary to this process and optimizing alum dosage will be more cost effective in running the AguaClara plant. To find an ideal alum dosage for a particular influent turbidity, we have varied the alum doses within certain ranges to verify which dosage works best for each situation. In addition to the use of alum, the optimization of the flocculator's length is critical. The length of the flocculator seems to have an influence on the optimum alum dose.

Through experiments, we aim to find the best combination of alum dosage and flocculator length that performs most efficiently.

Results and Discussion

Residual Turbidity Analysis

Results from 5 NTU experiments:
Both of our replicates (Fig. 1) for a flocculator of 28 m showed close agreement. Starting at a residual turbidity close to 5 NTU with an alum dose of 10mg/L, the residual turbidity dropped with increasing alum dose until it appeared to hit a limiting value of about 0.8 NTU with an alum dose of 50 mg/L. After this point, increasing alum dose no longer appeared to have an effect on residual turbidity. We hypothesize that initially, the flocs grow larger as alum dose is increased; the alum works as expected to cause the smaller particles to stick together and form larger flocs. However, as the flocs grow in size, they become larger, less dense and therefore more susceptible to breakup due to shearing forces. At a certain point. adding further coagulant can no longer hold the large flocs together, and the shearing forces cause them to begin breaking up. As a result, flocs cannot continue to grow larger, and as a consequence residual turbidity stops decreasing.

Figure 1: Residual turbidity vs. alum dose for 5 NTU influent water for a flocculator length of 2796cm.

For a flocculator length of 84 m, we focused on the lower alum dosages to see how the residual turbidity plot developed; experiments with higher alum dosages tended to show relatively constant residual turbidities around the minimum value achieved with low dosages (Fig.2). Here we see a similar trend to what was observed at 28 m, although the two replicates have a significantly different values at lower alum dosages. We suspect this is due to limits in the calibration of the pumps, combined with the possibility of blockages in the alum line and variations in influent turbidity, making it difficult to achieve consistent results at such low alum dosages.


Figure 2: Residual turbidity vs. alum dose for 5 NTU influent water for a flocculator length of 8388cm, focusing on lower alum dosages.

It appears that both flocculator lengths achieve similar minimum residual turbidity values of around 0.7 NTU (Fig. 3). However, the longer flocculator is able to achieve this with much lower alum dosages than the shorter one. Since shear rate was held constant, we hypothesize that the increased residence time of the longer flocculator allowed the flocs to grow larger with less alum since they had more time to collide before reaching the settling column. Although the minimum residual turbidity was achieved with lower alum dosages in the longer flocculator, it appears that increasing the length of the flocculator did not result in a lower residual turbidity than could otherwise have been achieved with the shorter flocculator using higher alum dosages. The dose of alum required to achieve an effluent turbidty of 1 was reduced by 30 mg/L to 10 mg/L by increasing Gθ from 22951 to 68853.


Figure 3: Comparison of residual turbidity vs. alum dose for two different flocculator lengths of 2796cm and 8388cm.

Results from 100 NTU experiments:
With 100 NTU water and a flocculator length of 28 m, we see a similar behavior to what was observed with 5 NTU influent water (Fig. 4). The residual turbidity starts out high before approaching a minimum value. However, this minimum residual turbidity increased from 0.6 NTU for 5 NTU water to 0.9-1 NTU for 100 NTU water. This is likely due to the fact that there is about 20 times as much clay initially as the 5 NTU experiments, making it much more difficult to achieve the same minimum residual turbidities.

Figure 4: Residual turbidity vs. alum dose for 100 NTU influent water for a flocculator length of 2796cm. A logarithmic scale is used on the residual turbidity axis to show details of the minimum residual turbidity achieved.

Both replicates at 56 m (Fig. 5) show the characteristic decay of residual turbidity to a limiting value. However, they do not agree at the low alum dosages; the second replicate shows a much lower residual turbidity for comparable alum doses at the low end of the curve. We suspect that there may have been a blockage in the alum line during the first experiment resulting in this irregularity. This is because alum doses as high as 20 mg/L produced a residual turbidity of around 80 NTU, much higher than would be expected. We then hypothesize that the blockage cleared by the fourth data point in the second replicate, and as a result both replicates achieved similar limiting residual turbidities of around 0.8 NTU.


Figure 5: Residual turbidity vs. alum dose for 100 NTU influent water for a flocculator length of 5592cm. A logarithmic scale is used on the residual turbidity axis to show details of the minimum residual turbidity achieved.

The three replicates of a flocculator length of 84 m at 100 NTU show reasonable agreement, as well as the same characteristic decay of residual turbidity observed in previous experiments (Fig. 6). However, the minimum residual turbidity achieved averaged around 1.6-2 NTU, significantly higher than observed at the previous two lengths. It appears that for a flocculator length of 84 m, the floc breakup behavior becomes more dominant, resulting in elevated residual turbdities.


Figure 6: Residual turbidity vs. alum dose for 100 NTU influent water for a flocculator length of 5592cm. A logarithmic scale is used on the residual turbidity axis to show details of the minimum residual turbidity achieved.

Comparing characteristic replicates from each of the three flocculator lengths, the same trend as seen with 5 NTU influent water is observed (Fig. 7), as the flocculator length is increased, a lower the alum dose is needed to achieve the minimum residual turbidity. When the flocculator is increased from 28 m to 56 m, the minimum residual turbidity decreases slightly from about 0.9 NTU to about 0.8 NTU. However, when it is further increased to 84 m, the residual turbidity jumps up to around 1.8 NTU. Therefore, it appears that while increasing flocculator length can produce favorable results as seen in the decrease in alum dose needed to achieve similar residual when comparing the two shorter lengths, further increases can be detrimental to flocculation performance.


Figure 7: Comparison of residual turbidity vs. alum dose for three different flocculator lengths of 2796cm, 5592cm, and 8388cm with influent water at 100 NTU. A logarithmic scale is used on the residual turbidity axis to show details of the minimum residual turbidity achieved.

Results from 500 NTU experiments:
For the 500 NTU experiments, similar minimal residual turbidities were achieved using flocculator lengths of 28 m and 8388cm of around 2 NTU. Additionally both showed similar behaviors to what was observed before. It is unclear if the 56 m flocculator achieved its minimum residual turbidity faster than the 2796cm flocculator since it is bounded on both sides by a 28 m replicate (Fig. 8). Further data is needed to draw conclusions regarding how flocculator length impacts residual turbidity with 500 NTU water.
The following results are from the experiments conducted with varying influent turbidity and flocculator length.


Figure 8: Comparison of residual turbidity vs. alum dose for two different flocculator lengths of 2796cm and 5592cm with influent water at 500 NTU.

Mean sedimentation velocities

Mean sedimentation velocities have a different evolution when increasing alum dose depending on the influent turbidity of the raw water (100 NTU and 500 NTU in the case of the experiments).

For a 100 NTU influent water, (figure 9 ), at a low alum dose, the mean sedimentation velocities of the flocs increase up to a maximum. Further increase in alum dose shows a decrease in the mean sedimentation velocity of the flocs. This could be explained by the fact that alum is less dense than clay. At low alum dose, alum precipitation allows the clay particles to stick to each other and to grow larger but the majority of the floc is clay. After a certain alum dose, the hypothesis is that flocs grow so big that they are vulnerable to shear stress and break up in the flocculator and then reflocculate. Equilibrium is then reached between floc break up and flocculation producing a similar distribution of particles sizes when increasing alum dose. It is hypothesized that when alum dose relative to clay increases, the floc density decreases and the mean sedimentation velocity decreases.


Figure 9: Plot of the mean sedimentation velocities as a function of alum dose for an effluent water of 500 NTU and a flocculator 2787 long

For an influent water of 500 NTU, the evolution of mean sedimentation velocities is different. Figure 10 below is a plot of the mean sedimentation velocity as a function of alum dose for an influent water of 500 NTU and a flocculator 2787 cm long. At low alum dose, mean sedimentation velocities increase with the alum dose. However, after a certain alum dose, mean sedimentation velocities reach a threshold. This could be explained by the fact that high turbidity water is flocculated quite quickly because the average time between two collisions of flocs is short and we hypothesize that flocs grow only to a certain point before they become too big and vulnerable to fluid shear stresses that break them. Like the 100 NTU water, after a characteristic time, a steady state is reached between flocculation and fragmentation and the floc size distributions stay constant. However, in the case of 500 NTU water, there is so much clay that increasing alum dose doesn't make the flocs less dense.


Figure 10: Plot of the mean sedimentation velocities as a function of alum dose for an effluent water of 100 NTU and a flocculator 2787 long

Mean sedimentation velocities are also influenced by the length of the flocculator. Figure 11 and 12, show mean sedimentation as a function of alum dose for three different lengths of flocculator. In figure 11, experiments were conducted with an influent water of 100 NTU and for figure 12, the experiments were conducted with an influent water of 500 NTU. On these two graphs the same trend can be observed when varying flocculator length. When the increasing flocculator length, the mean sedimentation velocities follow the same trend as alum dose increases but their corresponding magnitude decreases.


Figure 11: Plot of the mean sedimentation velocities as a function of alum dose for an effluent water of 100 NTU at different length of the flocculator (2787 cm, 5592 cm, 8388 cm)


Figure 12: Plot of the mean sedimentation velocities as a function of alum dose for an effluent water of 500 NTU at different length of the flocculator (2787 cm, 5592 cm, 8388 cm)

A few hypotheses seem plausible explaining floc break up in the flocculator. Flocs could break up because of interactions between particles and the wall or particles and the fluid or particles and particles. Comparing mean sedimentation velocities found for an influent water of 100 NTU and 500 NTU for the same length of flocculator (figure 13), it appears that the maximum mean sedimentation velocities are lower for a 500 NTU water than for a 100 NTU water. This result seems to validate the hypothesis that floc can be broken up because of particles-particles interactions. However, further investigation should be done in order to confirm the existence of this kind of interactions.


Figure 13: Plot of the mean sedimentation velocities as a function of alum dose, flocculator 2787 cm long, for an influent water of 100 NTU and 500 NTU

Reliability of the data

Replicability:

Every experiment was replicated to test the reliability of the results given by FReTA. The comparison between the mean residual turbidities of the experiments and their replicates has been explained in a revious paragraph. Mean sedimentation velocities were also compared. The figure 14,15 and 16 show that our experiments were quite accurate when analyzing mean sedimentation velocities.


Figure 14: Plot of the mean sedimentation velocities as a function of alum dose for an effluent water of 100 NTU at the smallest length of the flocculator (2787 cm)


Figure 15: Plot of the mean sedimentation velocities as a function of alum dose for an effluent water of 100 NTU at the medium length of the flocculator (5592 cm)


Figure 16: Plot of the mean sedimentation velocities as a function of alum dose for an effluent water of 500 NTU at the smallest length of the flocculator (2787 cm)

Mean sedimentation velocities :
The data processor retrieves mean sedimentation velocities of the particles at each alum dose during an experiment from our data. They are calculated when the data is fitted to a gamma distribution.

Since the mean sedimentation velocities are calculated when we fit the data, the mean sedimentation velocities given for a 5 NTU influent water are not accurate. Indeed, even if the data processor tries to fit the data, shape of the evolution of turbidity as a function of sedimentation velocity (figure 17) does not look like the fit function.


Figure 17: Plot of the turbidity vs sedimentation velocity for an influent water of 5 NTU. Flocculator 2787 cm long

For 100 NTU and 500 NTU, the fitted data seem accurate enough that we can trust the mean sedimentation velocities or the coefficient of variation retrieved. Data retrieved at low alum dosage seems to be really well fitted (figure 18). However, at higher alum concentrations, at some points, raw data seems to have a behavior slightly different than the gamma function (figure 19,20 and 21)


Figure 18: Plot of the normalized turbidity as a function of sedimentation velocity for the ram data and the fitted data. 500 NTU water, alum dose of 10 mg/L, flocculator 5592 cm long


Figure 19*: Plot of the normalized turbidity as a function of sedimentation velocity for the ram data and the fitted data. 500 NTU water, alum dose of 50 mg/L, flocculator 5592 cm long


Figure 20*: Plot of the normalized turbidity as a function of sedimentation velocity for the ram data and the fitted data. 500 NTU water, alum dose of 70 mg/L, flocculator 5592 cm long


Figure 21*: Plot of the normalized turbidity as a function of sedimentation velocity for the ram data and the fitted data. 100 NTU water, alum dose of 100 mg/L, flocculator 5592 cm long

  • No labels

1 Comment

  1. user-0a60b

    This page needs to be broken up into several sections. You need to re-write several of the sections.

    Try to condense your writing a little bit. It's great that you have collected and analyzed so much data, but I would recommend only presenting a good example of data acquisition in a "Data Analysis" section in your procedure section.

    For data that didn't fit the PDF curve, it was good that you speculated as to the causes of why it did not, but please condense this section as well.

    The results section needs to be updated to reflect the following changes. You should put an example of the results of your graphs in the data analysis section.

    In the results section, you should include representative plots of the data you obtained. It may be useful to include all data, but because you run so much I would recommend storing this data in other pages and perhaps put a link to these pages. You should also break up your section where you analyze particle size distribution and residual turbidity.

    The plots your created for residual turbidity are great and should be put in the results section, not the conclusion section. Refer to the figures in the conclusions section.

    I would recommend a summary plot for particle size distribution that included the the average particle size for the alum dose and turbidity. You should have two plots that compare one length to the other. I think it will be much easier for you to comment on the data then.