Accomplishments

  • met with Monroe briefly to determine set up of tube flocculator
  • ran uniform baffle configuration
  • determined equivalent dosage ratio relationship between PAC dose and alum dose
  • performed experiments on the uniform baffle configuration
  • organized pilot plant supplies
  • attempted to set up tube flocculator with t to let out air pressure
  • used peristaltic pump from sed tank to push water through tube settler
  • determined that 4 mg/L may be the optimum alum dosage based on the PAC dosage
  • performed experiments on the tapered baffle configuration

Issues

  • air in tube settler issue with gravity and pump
  • entering from connection?

Outcome

  • need to play around more with tube settler.
  • floc profile for floc tank
  • No labels