Linear Flow Orifice Meter Design for 700 L/min Flow Rate

The LFOM design with the smallest percent error has an initial H.flowloc = 1.5cm, and Pi.Lfomorifice = 20

This is a visual representation of the Riser pipe

This is the tabular form of the design

  • The diameter is equal to 0.953 cm

    Row

    Height, cm

    Number of orifices

    0

    0

    36

    1

    2

    23

    2

    3

    10

    3

    4

    10

    4

    5

    8

    5

    6

    8

    6

    7

    7

    7

    8

    7

    8

    9

    6

    9

    10

    6

    10

    11

    6

    11

    12

    5

    12

    13

    5

    13

    14

    5

    14

    15

    5

    15

    16

    5

    16

    17

    4

    17

    18

    5

    18

    19

    4

    19

    20

    4

  • No labels