Linear Flow Orifice Meter Design for 700 L/min Flow Rate
The LFOM design with the smallest percent error has an initial H.flowloc = 1.5cm, and Pi.Lfomorifice = 20
This is a visual representation of the Riser pipe
This is the tabular form of the design
- The diameter is equal to 0.953 cm
Row
Height, cm
Number of orifices
0
0
36
1
2
23
2
3
10
3
4
10
4
5
8
5
6
8
6
7
7
7
8
7
8
9
6
9
10
6
10
11
6
11
12
5
12
13
5
13
14
5
14
15
5
15
16
5
16
17
4
17
18
5
18
19
4
19
20
4