Linear Flow Orifice Meter Design for 300 L/min Flow Rate

The LFOM design with the smallest percent error has an initial H.flowloc = 1.5cm, and Pi.Lfomorifice = 20

This is a visual representation of the Riser pipe

This is the tabular form of the design

  • The diameter is equal to 0.953 cm

    Row

    Height, cm

    Number of orifices

    0

    0

    15

    1

    2

    11

    2

    3

    4

    3

    4

    4

    4

    5

    3

    5

    6

    4

    6

    7

    3

    7

    8

    2

    8

    9

    4

    9

    10

    1

    10

    11

    4

    11

    12

    1

    12

    13

    3

    13

    14

    2

    14

    15

    2

    15

    16

    2

    16

    17

    2

    17

    18

    2

    18

    19

    2

    19

    20

    1