Linear Flow Orifice Meter Design for 200 L/min Flow Rate
The LFOM design with the smallest percent error has an initial H.flowloc = 1.5cm, and Pi.Lfomorifice
This is a visual representation of the Riser pipe
This is the tabular form of the design
- The diameter is equal to 0.794 cm
Row
Height, cm
Number of orifices
0
0
15
1
2
9
2
3
4
3
4
5
4
5
3
5
6
3
6
7
3
7
8
3
8
9
2
9
10
3
10
11
2
11
12
2
12
13
3
13
14
1
14
15
3
15
16
1
16
17
2
17
18
2
18
19
2
19
20
2