Linear Flow Orifice Meter Design for 100 L/min Flow Rate
The LFOM design with the smallest percent error has an initial H.flowloc = 1.5cm, and Pi.Lfomorifice = 20
This is a visual representation of the Riser pipe
This is the tabular form of the design
- The diameter is equal to 0.794 cm
Row
Height, cm
Number of orifices
0
0
7
1
2
6
2
3
1
3
4
2
4
5
2
5
6
2
6
7
1
7
8
1
8
9
2
9
10
1
10
11
1
11
12
1
12
13
1
13
14
1
14
15
2
15
16
0
16
17
1
17
18
1
18
19
1
19
20
1