You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 9 Next »

Overview of Methods

In order to experimentally define the critical velocity at which floc roll up begins, flow rates through the tube settler were increased incrementally utilizing a ramp state function in process control software.

By incrementally increasing the flow rate through the tube settler, we can compare the effluent turbidity performance over time. A critical velocity could be identified based upon effluent performance and compared to our theoretical model. The critical velocity is when the velocity on the outer edge of the floc particle is equal to the floc settling velocity. Any velocity exceeding the critical velocity is when floc roll up begins.

Using the same experimental apparatus as was used in Summer 2009 and Spring 2009, and the ramp state process controller function, we hope to prove that the understand if our theoretical model of floc roll up behavior is accurate describes system behavior. Ultimately, we hope to minimize the floc roll up in the plate settlers and further reduce the effluent turbidity.

Results and Discussion

By running the ramp state function on different tube settler diameters, we hope to further develop the relationship between plate settler size and floc roll up.

Experiment 1- Ramp State with 9.5 mm tube

Experiment 2- Ramp State with 15.3 mm tube

Conclusions

  • No labels