Linear Flow Orifice Meter Design for 500 L/min Flow Rate and 10 rows
The LFOM design with the eaiest construction has an initial H.flowloc = 1.5cm, and Pi.Lfomorifice = 10
This is a visual representation of the Riser pipe
This is the tabular form of the design
- The diameter is equal to 1.587 cm
Row
Height, cm
Number of orifices
0
0
9
1
2
7
2
4
5
3
6
5
4
8
3
5
10
3
6
12
2
7
14
3
8
16
3
9
18
2
10
20
2