Gtheta Computations using UDF

A User Defined FLUENT script (UDF) was created to extract the G_theta value from the flocculator. The UDF loops through all of the individual cells of the converged solution, and extracts the energy dissipation^1/2 times the cell area. The sum of this quantity for all cells divided by flow and square of viscoisty results in the G_theta value of the entire flocculator as shown in equation 1.

   Gθ_baffle=1/Q*vis^(-1/2)*∑(ε^(1/2)*cell_area)   Eq. 1

The above formulation has been determined (with Monroe's help) by weighting the value of Gθ by volume.

   

The Gθ_baffle values weighted by the area or number of cells were also examined, but these formulations do not produce sensible results.

Below is the G_theta value presented for flocculation tanks of different geometries:

Case Geometry (h-height,b-width,N-baffles)

Gθ_Flocculator

b=.1, h=1, N=1, Clearance height=.15

430

b=.1, h=.3, N=5, sym bc

1330

b=.1, h=.2, N=5

1060