So if you are a new students in Tube Floc team, here are some basics that you need to know.

Checklist for the setup

  • Make sure all connection is tight.
  • Make sure that there is no clogging in the floc and pump tubes
  • Check the tube size (both pump and floc) and the pump panel setup
  • The data connectors are easily unplugged, so check them out!

 

Amount of water

Amount stock added

Stock concentration

 

Liter

gram

g/L

Clay

11

22.2

2.02

Alum

11

16.5

1.5

Humic acid

 

0.375

3.5 mg/L

Process Controller

Troubleshooting

What to do if you don't see any flocs forming in the settling tube?

*Always check tube connections and make sure there is no clogging in the connections.
*Check the stock solutions. Make sure that there is no sedimentation occurring in clay and alum stock solutions.
*Check the influent turbidimeter. If it displays lower turbidity, then check the clay and alum stock solutions. Check if the flow coming out of the pumps. Check clay/alum flowrates with timer and graduated cylinder. Change in the process controller so that it will give correct value of clay/alum.
*Check bubbles in the floc and settling tubes, especially at the influent of the settling tube. Flocs could get trapped in the bubbles.