On Windows systems, select the appropriate menu path. On my system, the path is
Start > Programs > ANSYS 10.0 > ANSYS Product Launcher
Enter the location of the folder shell that you just created as your Working directory by browsing to it.
Enter shell as your Initial jobname_. _ Click on Run_. _
Resize windows as shown in this snapshot so that you can read instructions in your browser window and implement them in ANSYS.

...

We'll play smart and create scalar parameters corresponding to the plate and stiffener dimensions_._ This will later allow us to vary these parameters and perform optimization studies.
Utility Menu > Parameters > Scalar Parameters
Define a parameter for the plate length l1 in mm:
L1=750
Click Accept. Similarly, define other parameters corresponding to the dimensions and click Accept after each (parameter names are not case-sensitive). Before you specify a parameter, refer to the geometry specification to remind yourself what dimension that parameter represents.


W1=250
W2=2
W3=2
H1=5
H2=15
H3=20

{{}}
We'll play smarter and also specify the number of stiffeners in each direction as parameters so that these too can be varied easily in tradeoff studies. We'll employ the labels NSX and NSY for the number of stiffeners in the x and y directions, respectively.


NSX=2
NSY=3


We'll use the above parameters when creating the geometry in Step 4. We'll also define some parameters which we'll use in Step 5 to set the mesh size along edges.


NDIV_X=3
NDIV_Y=6
SIZE_Z=5


Close the Scalar Parameters window.
Go to Step 2: Specify Element Types and Constants |

...