!Pilot Plant Construction and Research^CAD drawing of sed
tank.jpg!
Below is a table of the calculated pipe dimensions and other calculated design parameters. The method behind each number can be found in the following design.
Parameter | Value |
---|---|
Inlet Pipe | 4 in |
Launder Diameter | 2 in |
Number of Holes | 15 |
Hole Diameter | 3/16in |
Tank Drain Diameter | 1.5in |
Number of Holes | 15 |
Hole Diameter |
|
Secondary Outlet Weir Diameter | 3in |
Weir Height | 30.5 in |
Hopper Removal Diameter | 0.5in |
Hopper Removal Line Length | 2m |
Upward Velocity Calculation:
To determine the upward velocity of the sedimentation tank the flow rate through the tank was divided be the cross sectional area of the tank. In order to make our model comparable to the sedimentation tanks that are built on a full scale the upward velocity needs to be the same. The upward velocity in Ojojona was found to be 100m/day. Thus this was the parameter we used for this model as well.
...