Include Page
FLUENT Google Analytics
FLUENT Google Analytics
Include Page
3D Bifurcating Artery (steady) - Panel
3D Bifurcating Artery (steady) - Panel

Physics Setup

Solution Setup

Watch the following video for demonstrations: coming soon

Summary for the video:

  1. General → Display Mesh, Check Mesh, Enable Gravity
  2. Materials → Fluid → Change "Name" to "Blood" → Change "Density" to 1060 kg/m^3, Change "Viscosity" to 0.0035 Pa-s (based on the infinite shear viscosity of blood)

Boundary Conditions

Watch the following video for demonstrations: coming soon

Summary for the video:

  1. Boundary Conditions → Inlet → Velocity Inlet → Edit → Change "Velocity Magnitude" to 0.315 m/s
  2. Outlet1 → Pressure Outlet → Edit → Change "Gauge Pressure" to 0.
  3. Outlet2 → repeat the steps for Outlet1. 
  4. Operating Conditions → Change "Operating Pressure" to 13332 Pa (100 mmHg)

Go to Step 5: Numerical Solution