Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

The table below compares the calculated and simulated values for maximum stress in the plate with a hole. With a difference of less than 5% we can consider our simulation to be accurate. This small difference in results may be caused by not using enough mesh refinement.

 

Simulated Value

Calculated Value

Difference

3.089E6 psi

3.033E6 psi

1.81%

 

Go to all (ANSYS or FLUENT) Learning Modules